Skip to content
ARRF
▦ All products
StrandCalls R1-MCP ARRF CP-MCP CP Word List ICX Setup Docs coming soon Probe MCP Docs coming soon SZ-MCP Docs coming soon Tangent MCP Docs coming soon NeuralRepo docs.neuralrepo.com
Get Support

Settings reference

The Settings tab holds accounts and defaults. The where of a specific survey (venue or APs) is chosen in the Survey lobby; Settings holds everything else. This page lists each section and its real defaults.

Connect a RUCKUS One tenant to survey by venue with automatic AP passwords. Region (default North America), tenant ID, client ID, and client secret (Keychain-only), plus Test connection and Disconnect. Full details in Setting up a RUCKUS One account.

  • Target SSID — the WLAN surveys poll. Default empty; set it here or via the SSID picker.
  • APs — the manual AP IP list (2–5) and per-AP SSH passwords (Keychain, per IP). Default empty.

Surveys log into each AP’s CLI over SSH (TCP 22) and read the AP-measured signal at ~2.5 Hz. See Connecting to your RUCKUS APs.

Find my device picks the Wi-Fi client the survey follows. Under Advanced you can type the target MAC by hand (default empty). See Find my device.

SettingDefaultNotes
Placement throttle0.3 mMinimum distance between cubes (0–2 m).
Live cube interval1.0 sMinimum time between continuous cubes (0.4–5 s).
Floor-plan reconstructionOnBuilds a LiDAR floor plan; takes effect next survey.
Deep RF stats per cubeOffExtra radio detail per cube, at one extra AP query each.
Show survey instructionsOnThe “How to run a survey” card on each survey’s first appearance.

The capture mode (Continuous vs Stop & sample) is picked in the survey lobby, not here.

SettingDefaultNotes
Roam markersOnDraw a post at each handoff (also on the HUD).
AP location signsOnFloat an estimated-position sign per AP.
Cube coloursSignal (dBm)The metric the cube fill encodes.
Cube label fieldsAP name, Signal, Uplink ↑, Downlink ↓Up to four near-label fields.
Behind wallsDimmedHow LiDAR-occluded cubes are drawn (Off / Hide / Dimmed).

See Cube colors, labels, and detail and AP locations and roaming.

  • Use true noise floor — default off; when off, ARRF uses a flat dBm offset.
  • dBm offset — default −96, which matches the RUCKUS One dashboard (dBm = SNR + offset). “True noise floor” uses the per-radio measured floor instead (5 GHz ≈ −99).

The targets the survey grade scores against, captured into every export:

TargetDefault
Primary target−67 dBm
Edge target−72 dBm
Min SNR25 dB

Signal is the serving AP’s uplink RSSI/SNR — how the AP hears the phone, not a coverage map. See Results and the survey grade.

Company and Engineer are stamped on exported PDF reports. Leave blank to omit.

Links to the Privacy Policy and Terms of Use. ARRF runs entirely on your device — no account, no backend.